Encana Corporation

Closed Expression of Interest:S-02-00/S-04-00

EXPRESSION OF INTEREST (EOI)
SUPPLY OF JACKET PILES AND WELDED TUBULARS & CONES
BIDS Category: 2815 (PILES) and 2810 (TUBULARS AND CONES)
Reference: S-02-00 (PILES) and S-04-00 (TUBULARS AND CONES)
Issue Date: June 4, 2002
Closing Date: June 19, 2002

EnCana Corporation is proposing to develop its Deep Panuke gas prospect located offshore Nova Scotia, approximately 44 km to the West of Sable Island. The proposed development plan comprises three new platforms - a production platform (DPP), a utilities and quarters platform (UQP) and a wellhead platform (WHP) - with two interconnecting bridges linking them to each other. Up to 6 wells will provide production from the Deep Panuke development. Gas will be delivered to shore via one new export pipeline, of 24" NPS after processing offshore. The onshore landfall site for the export line will be in the Goldboro region.

EnCana Corporation has appointed Accent-Saipem Energy Joint Venture to provide the Engineering Design study for this project.

During this phase we are seeking qualified companies for the supply of jacket piles (S02-00) and welded tubulars and cones (S04-00) from Type 1 and Type 2 primary structural steel with the following characteristics:

Physical Data:
Approximate quantity (Types 1 and 2 combined) Thickness range Diameter range Maximum Length Minimum Length 1 S02-00 4,500 tonnes 60-90 mm 2,134mm 80,000mm 3,500mm 2 S04-00 4,000 tonnes 12-90 mm 700-3,000mm 16,000mm 3,500mm

Steel Properties:
Carbon Equivalent (max):
Through thickness (Z) properties (CV2Z / CV2ZX):
Specified Minimum Yield Strength (Type 1):
Specified Minimum Yield Strength (Type 2):
Charpy V notch impact: (CV1 / CV1X) (CV2 / CV2Z) (CV2X / CV2ZX)
NDT drop weight: (CV1) (CV2) (CV2X)
CTOD HAZ for t > 40 mm: (CV1X) (CV2X / CV2ZX)

Notes: 0.43% 35% min STRA; 0.005% max. S for t > 25mm 450 MPa for t = 25mm; 415 MPa for t > 25mm 350 MPa 45 J avg / 32 J min at -30ºC 45 J avg / 32 J min at -40ºC for t = 40mm 45 J avg / 32 J min at -50ºC for t > 40mm No break at -30ºC No break at -40ºC No break at -50ºC 0.25 mm at 0ºC (S02-00) 0.25 mm at -20ºC(S04-00)

1. CV1 etc. = ISO steel toughness class
2. CV1X = CTOD HAZ testing for jacket piles (S02-00) only

Prequalification Data:
HAZ CTOD:
Strain-age testing: As above
Strained 5%, aged at 250ºC for 1 hour,
for greatest plate t and CE;
CVN impact tested at -50ºC as above
Bead on plate per BS7191

Circumferential and Longitudinal Seam Welding Data:
Weld Procedure Qualification:
Welder Qualification:
Inspection of production welds: EEMUA 158 Guidelines, or recognised equivalent;
Weld metal CTOD requirements for t > 40mm as for steel data;
AWS D1.1, or recognised equivalent;
Monitoring / NDE as per EEMUA 158, or recognised equivalent.

Respondents will be required to provide evidence that welding procedures satisfy the above noted qualification requirements.

Suppliers may respond to this EOI assuming either or both of the following options:
- Supplier will source and supply steel Types 1 and 2
- EnCana will free issue steel Types 1 and 2

Suppliers who source and procure the steel will also be required to provide supporting evidence that the purchased primary steel satisfies the properties and prequalification weldability / fabricability requirements summarised above.

A Supplier Prequalification Questionnaire must be submitted, including all data pertinent to your Scope of Supply, with your Expression of Interest. To obtain the Prequalification Questionnaire please contact BIDS Nova Scotia (see contact information below).

Bidders do not necessarily have to express interest in the complete package. The package may be split.

Interested parties are required to have an implemented Quality Management System that meets the requirement of the ISO-9000 series of Standards and Safety Management System(s). Respondents must indicate company name, contact details, managers and key personnel, company profile, and summary of related experience as requested in the Supplier Prequalification Questionnaire. The Deep Panuke Project will select qualified bidders from among the respondents to this EOI. Expressions of Interest must be received on or before June 19, 2002.

All inquires and Expression of Interest must be clearly marked with the EOI reference number and should be directed to: D. Long Project Buyer Deep Panuke Project 7th Floor, Royal Centre 5161 George Street Halifax, NS B3J 1M7 Fax: 902-425-2766 Don.long@encana.com

IN ADDITION: POTENTIAL SUPPLIERS FOR THIS PROJECT, IF THEY HAVE NOT ALREADY DONE SO, MUST REGISTER THEIR COMPANIES BY CONTACTING BIDS NOVA SCOTIA AT: Phone: 902-462-4824 1-800-397-0393 Email: bids@istar.ca